Direct Current Motor

Saturday, August 16, 2008 in DC Motor

Direct Current Motor

Direct Current Motor

Gerenal Description
1. To develop this direct current motor, the rotor diameters of all shaft center heights are optimized, the electrical loading and the magnetic loading of inertia/torque ratio and excellent suitability to impact, faster changed loads dc motor.
2. The connection between the commutator and the coils use TIG welding. To prevent the commutator risers from breaking and welding failure,special measures have been taken to fix the commutator risers. For frequent starting reversible mill motors, the commutator risers are constructed to be integral.
3. Both stator and rotor of series direct current motor is vacuum pressure impregnated with F class insulation, thus the winding has excellent anti-humidity performance, mechanical strength, and insulation thermal conductivity. The machine is applicable to be used in the humid tropical regions.
4. For the enclosure protection degree, the dc motor of this series are of IP23 and IP44 of GB4942.1 and IEC34-5<Classification of Enclosure Protection of electric machines. As to the type of cooling, the motors of this series are of ICO6,ICW37AB6 of GB1993 and IEC34-6<Type of cooling of Electric Machines. Other types of cooling and enclosure protection degree are also possible by separate agreement if required.
 
Basic Characteristics
1. The designed rating of series dc motors is based on continuous operation (s1).
2. There are totally 8 rated voltage grade to be selected for this series direct current motors, they are 220V,330V,440V,550v,660v,750v,850v,and 950v.the voltage beyond above scope can also be adopted on request.
3. Separate excitation is the basic excitation type of this series motors. Four terminals of the excitation winding are divided into two groups. In cases the two groups are in series or parallel connection, the excitation voltage is 220v or 110v respectively. Excitation voltage beyond above scope is also available on request. Forced excitation is allowed with the voltage less than 500v, during forced excitation, the transient excitation current can exceed the rated excitation current slightly until the excitation current gets stabilized. 

Z 355-3A
Series
Speed under Rated voltage (r/min)
Output
Rated Current
Efficiency
Max Speed
EX output
Rotation Inertia
ventilation
Rotor Circuit
Quantity
Pressure
Voltage
Sense
220V
330V
440V
550V
660V
PN
IN
η
nmax
Pf
J
Q
H
△U
La
kW
A
%
r/min
kW
kg.m2
M3/S
Pa
V
mH
01
184
 
 
 
 
55
329
71.5
600
4.6
11
1.5
1430
52.1
1.7
 
307
 
 
 
90
326
80.4
1000
4.6
11
1.5
1430
51.1
1.6
 
 
453
 
 
132
344
84.6
1500
4.6
11
1.5
1430
50.7
1.4
 
 
 
558
 
160
323
87.8
1500
4.6
11
1.5
1430
49.9
1.5
 
 
 
 
709
200
331
89.9
1500
4.6
11
1.5
1430
49.3
1.3
02
248
 
 
 
 
75
421
77.2
800
4.5
11
1.4
1270
40.2
1
 
443
 
 
 
132
457
85
1500
4.5
11
1.5
1430
39.6
0.78
 
 
550
 
 
160
405
87.7
1500
4.5
11
1.5
1430
38.7
0.94
 
 
 
772
 
220
437
89.8
1500
4.5
11
1.5
1430
38.1
0.78
 
 
 
 
898
250
409
91.1
1500
4.5
11
1.5
1430
37.2
0.86
03
382
 
 
 
 
110
590
82
1200
4.5
11.3
1.5
1430
31.2
0.47
 
568
 
 
 
160
543
87.1
1500
4.5
11.3
1.5
1430
30.5
0.51
 
 
805
 
 
220
545
90.2
1500
4.5
11.3
1.5
1430
29.8
0.48
 
 
 
1057
 
280
549
91.5
1500
4.5
11.3
1.6
1610
28.9
0.45
 
 
 
 
1235
315
510
92.4
1500
4.5
11.3
1.6
1610
28
0.5
04
456
 
 
 
 
132
689
84.6
1500
4.6
12
1.5
1430
25.6
0.33
 
658
 
 
 
185
617
88.9
1500
4.6
12
1.5
1430
25.1
0.39
 
 
922
 
 
250
614
91
1500
4.6
12
1.6
1610
24.4
0.37
 
 
 
1214
 
315
614
92.1
1500
4.6
12
1.6
1610
23.2
0.35
 
 
 
 
1442
355
571
93.1
1500
4.6
12
1.7
1800
22.3
0.38
05
557
 
 
 
 
160
813
87.2
1500
4.7
12
1.5
1430
19.8
0.23
 
913
 
 
 
250
821
90.7
1500
4.7
12
1.6
1610
19.1
0.21
 
 
1219
 
 
315
764
92.5
1500
4.7
12
1.7
1800
18.1
0.23
 
 
 
1540
 
371
716
93.1
1540
4.7
12
1.8
2000
17.1
0.24

 

Related Products

address